{"id":911,"date":"2023-11-30T07:39:00","date_gmt":"2023-11-30T07:39:00","guid":{"rendered":"https:\/\/greentek.vn\/san-pham\/2-component-glue-sprayer-with-ratio-from-11-to-121\/"},"modified":"2023-11-30T07:39:00","modified_gmt":"2023-11-30T07:39:00","slug":"2-component-glue-sprayer-with-ratio-from-11-to-121","status":"publish","type":"product","link":"https:\/\/greentek.vn\/en\/san-pham\/2-component-glue-sprayer-with-ratio-from-11-to-121\/","title":{"rendered":"2-component glue sprayer with ratio from 1:1 to 12:1"},"content":{"rendered":"<p>The PR70 is a superior dispensing solution for a broad range of applications, including bonding and sealing, potting, gasketing, encapsulation and syringe filling. All the features you need, in a compact, modular design.<\/p>\n<p>Medium to low density materials Excellent performance with materials from 1:1 to 12:1 High pressure precision MD2 valve with multiple seat styles and adjustable snuff back function for separation Coordinate cleanly and accurately.<\/p>\n<table id=\"table-specifications\" class=\"table table--convertible table-striped metric is-expanded\">\n<tbody class=\"converted-value\">\n<tr>\n<th scope=\"row\">Air Inlet Size (cm)<\/th>\n<td class=\"text-align--right\"><strong>0.635<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Air Inlet Size (in)<\/th>\n<td class=\"text-align--right\"><strong>1\/4<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Air Inlet Size (mm)<\/th>\n<td class=\"text-align--right\"><strong>6.35<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Air Inlet Thread Gender<\/th>\n<td class=\"text-align--right\"><strong>Female<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Air Inlet Thread Type<\/th>\n<td class=\"text-align--right\"><strong>NPT<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Component Type<\/th>\n<td class=\"text-align--right\"><strong>Two Component<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Controls<\/th>\n<td class=\"text-align--right\"><strong>Yes<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Effective Area (mm\u00b2)<\/th>\n<td class=\"text-align--right\"><strong>80-960<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Fixed\/Variable Ratio<\/th>\n<td class=\"text-align--right\"><strong>Fixed<\/strong><\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flow Control Type<\/th>\n<td class=\"text-align--right\"><strong>Fluid Flow Control<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Fluid Outlet Size (in)<\/th>\n<td class=\"text-align--right\"><strong>3\/16, 1\/4, 3\/8, 1\/2, 3\/4<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Frequency (Hz)<\/th>\n<td class=\"text-align--right\"><strong>50\/60<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Large Air Cylinder Effective Area (mm\u00b2)<\/th>\n<td class=\"text-align--right\"><strong>10260<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Air Inlet Pressure (bar)<\/th>\n<td class=\"text-align--right\"><strong>6.9<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Air Inlet Pressure (kPa)<\/th>\n<td class=\"text-align--right\"><strong>690<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Air Inlet Pressure (psi)<\/th>\n<td class=\"text-align--right\"><strong>100<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Cycle Rate (cpm)<\/th>\n<td class=\"text-align--right\"><strong>30<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Fluid Working Pressure (MPa)<\/th>\n<td class=\"text-align--right\"><strong>20.68<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Fluid Working Pressure (bar)<\/th>\n<td class=\"text-align--right\"><strong>206.8<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Fluid Working Pressure (psi)<\/th>\n<td class=\"text-align--right\"><strong>3000<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Operating Temperature (\u00b0C)<\/th>\n<td class=\"text-align--right\"><strong>70, 50<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Stroke Length (mm)<\/th>\n<td class=\"text-align--right\"><strong>38.1<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Working Pressure (MPa)<\/th>\n<td class=\"text-align--right\"><strong>21<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Working Pressure (bar)<\/th>\n<td class=\"text-align--right\"><strong>207<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Working Pressure (kPa)<\/th>\n<td class=\"text-align--right\"><strong>20700<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Maximum Working Pressure (psi)<\/th>\n<td class=\"text-align--right\"><strong>3000<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Minimum Stroke Length (mm)<\/th>\n<td class=\"text-align--right\"><strong>5.8<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Mix Ratio<\/th>\n<td class=\"text-align--right\"><strong>1:1-12:1<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Model<\/th>\n<td class=\"text-align--right\"><strong>PR70<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Overall Depth (cm)<\/th>\n<td class=\"text-align--right\"><strong>77.7<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Overall Depth (mm)<\/th>\n<td class=\"text-align--right\"><strong>777<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Phase<\/th>\n<td class=\"text-align--right\"><strong>1<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Power Input (V)<\/th>\n<td class=\"text-align--right\"><strong>100-240, 208-240, 120, 240<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Pump Cycles per 1l<\/th>\n<td class=\"text-align--right\"><strong>14.3-500<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Pump Ratio<\/th>\n<td class=\"text-align--right\"><strong>1:1, 12:1<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Small Air Cylinder Effective Area (mm\u00b2)<\/th>\n<td class=\"text-align--right\"><strong>4560<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Type<\/th>\n<td class=\"text-align--right\"><strong>Dispensing System<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Volume Per Cycle (cc)<\/th>\n<td class=\"text-align--right\"><strong>2-70<\/strong><\/td>\n<\/tr>\n<tr class=\"expandable-table-row\">\n<th scope=\"row\">Wetted Material<\/th>\n<td class=\"text-align--right\"><strong>Carbide, Hard Chrome, Nylon, 303 Stainless Steel, Chromex, PTFE, UHMWPE, 304 Stainless Steel<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Accurately dispense two-component low- to high-viscosity materials with Greentek PR70 Meter, Mix and Dispense Systems. The PR70 is a superior dispensing solution for a broad range of applications, including bonding and sealing, potting, gasketing, encapsulation and syringe filling.<\/p>\n<p>Benchtop unit provides precise mix ratio and shot repeatability<br \/>\nExceptional performance with material ratios from 1:1 to 24:1<br \/>\nDispenses water thin to paste consistency from 2.0 to 70 cc\u2019s<br \/>\nProven ratio accuracy to \u00b11%<br \/>\nOperator actuated or integrated with machine automation<br \/>\nAvailable in fixed or variable ratio models<\/p>\n","protected":false},"featured_media":835,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}}},"product_cat":[57],"product_tag":[],"class_list":{"0":"post-911","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-glue-sprayer","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","10":"ast-product-gallery-layout-horizontal-slider","11":"ast-product-gallery-with-no-image","12":"ast-magnify-disabled","13":"ast-product-tabs-layout-accordion","15":"first","16":"instock","17":"shipping-taxable","18":"product-type-simple"},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/product\/911","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/comments?post=911"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/media\/835"}],"wp:attachment":[{"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/media?parent=911"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/product_cat?post=911"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/greentek.vn\/en\/wp-json\/wp\/v2\/product_tag?post=911"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}